Three scenarios, three designs
Mounting APs is the same act in all three, but offices, guest rooms and outdoor areas fail for completely different reasons. Applying one template everywhere is the most common cause of poor coverage.
Open-plan office
The hard part: dense desks, high concurrency, and partitions or glass curtain walls that block and reflect signal. The design focus is capacity and interference control, not range.
Hotel rooms / dormitories
The hard part: every room is its own small box, and a corridor AP will not get inside. An in-wall wall-plate AP is the reliable answer, and it blends into the fit-out.
Outdoor and campus
The hard part: sun, rain, lightning and long backhaul runs. That means an IP67 body, surge protection and bridge or fiber backhaul.
Retail and chains
The hard part: many sites, no IT staff on site, and downtime that closes the shop. Hardware must be plug-and-play, cloud-manageable, and every store visible from head office.
Four steps: capacity and cost
Site survey
Read the drawings, measure ceiling height, confirm wall materials and partitions, locate the power and data risers, and mark where you cannot drill. Every later number depends on this being right.
Capacity calculation
Count peak concurrent clients per zone, not people, add the per-client bandwidth requirement, and work back to how many APs each zone needs and the per-unit client limit. Meeting rooms and open desks are calculated separately.
RF and channel planning
On 2.4 GHz only the three non-overlapping channels 1, 6 and 11 are used, staggered between adjacent APs; 5 GHz starts at 160 MHz and drops to 80 MHz where interference demands it. The output is a channel map that avoids co-channel interference.
Acceptance
Before handover we measure signal strength and throughput across the whole area and issue heat maps plus a per-AP report. The acceptance thresholds, which spot must reach how many dBm and Mbps, are written into the contract.
Product mix
The line covers four forms — ceiling, wall-plate, outdoor and bridge — with two controllers. Specifications live on the product pages; what follows is the selection logic.
Wi-Fi 6 dual-band
2.5G uplink
86-box mount
4T4R, surge protected
| Scenario | Recommended model | Why |
|---|---|---|
| Open office (ceiling 2.8–3.5 m) | AI6220 / AIH-6221 | Ceiling mount with a controlled coverage radius; the 2.5G uplink suits backhaul in dense zones |
| Hotel rooms / dorms / cellular offices | AIH-622 (wall-plate) | Fits an 86 box in the wall; signal enters the room directly instead of pushing through from the corridor |
| Campus perimeter / car park / loading dock | AO6220 | IP67 body, surge board and high-power FEM, built for temperature swings, rain and snow |
| Multi-site management | AC1600 / AC2600 | AC1600 fits in a distribution box and manages 64 APs; AC2600 manages 128 with 4G/5G failover |
| Between buildings / lifts / long-range backhaul | Wireless bridge range | 10–30 km line-of-sight backhaul with no cabling; lift shafts use a dedicated car-mounted bridge |
Architecture: three tiers, one thread
The standard build is three tiers: the core switch handles routing and policy, floor PoE switches provide power and access, and the APs do nothing but radio. Controllers, location engines and wireless intrusion prevention hang off the core.
Core switch / gateway
Handles VLAN segmentation, inter-subnet routing, egress policy and hosts the controller out-of-band. Dual chassis is optional, depending on how much downtime the business tolerates.
Floor PoE switches
One cable carries both power and backhaul, removing a mains drop at every point. Uplinks run to the core over single-mode gigabit fiber.
APs and clients
Fat or fit in one box: a small site runs standalone, and multi-site estates switch to fit mode for central configuration and upgrades.
Controller / location / WIPS
Pushes uniform configuration, tunes RF and sets roaming policy; UWB location and wireless intrusion prevention are added as needed on the same APs.
Five common problems
| Symptom | Real cause and what to do |
|---|---|
| Full bars, slow network | Co-channel interference or channel planning that has failed. More APs will not fix it; redo the channel and power plan |
| Drops and reconnects when you walk next door | Roaming is not configured, or the APs do not share one SSID and key. Put them under a controller |
| Meeting rooms stall as soon as people join | Planned by headcount instead of concurrent clients, so capacity is short. Dense rooms need extra APs |
| Signal will not reach the guest rooms | Corridor ceiling APs trying to punch through two walls. Switch to in-wall wall-plate APs |
| Devices fail en masse after two years | Indoor models used outdoors, or no surge grounding. Check the protection rating at selection time |
Delivery and acceptance
We hand over more than installed hardware. Three artifacts stay with you:
Coverage heat maps
Signal strength and SNR per floor, with weak zones marked and the remediation already applied noted.
AP and channel schedule
Mounting position, orientation, channel, power and VLAN for every AP, filed at handover so later expansion follows the same plan.
Client experience test report
Measured throughput and roaming at representative desks, meeting rooms and corridors, with handover time and packet loss recorded.
Operations handover
Platform accounts, alert rules and a runbook for common issues, written so your IT team can take over directly.