Opened the wrong way — this page has no styling and no images.
Image and stylesheet paths are resolved from the site root (/assets/…), so opening the file directly resolves them to C:\assets\… and nothing loads.
To see it properly: unzip 2_双击进后台改字_仅Windows.zip and double-click 启动后台.bat — the browser then shows the full site with styling, images and the ZH/EN switch.
(This zip is a plain static preview: opened directly it shows one page at a time, without styles, images or the language switch.)
Once uploaded it works normally: live traffic arrives over http, not by double-clicking a file.
This notice only appears when the file is opened locally; online visitors never see it.
ProductsWireless access & coverageSwitching & data centerOptical access & transportOptics & cabling
ServicesManaged NOCImplementation & deliverySpare parts & maintenanceAdvisory & architecture
SolutionsManaged network operations & NOCCampus & wireless coverageCloud-network branchesSecurity & compliance
Case studiesScale · managed operationsSpeed · bulk migrationContinuity · legacy retrofitTechnical notes
About usCompany profileCertificationsOffices & contactTechnical notes
Resources & contactTechnical notesFAQDelivery processPricingPrivacy & termsContact usOffice address
Home / Products / Optical communications & cabling

Optical modules, cables and cabling: 1G to 200G

The physical layer of data centers and campus backbones: optical modules, AOC, DAC, MPO and LC patch cords from 1G to 200G. We match rate, wavelength, reach and connector item by item, so nothing is paired wrong.

1G–200G
Six rate classes
8/12 fibers
MPO Type B polarity
≤0.35dB
MPO Elite low loss
IL/RL
Per-cord test label
Optical modules and patch cords
Modules · AOC/DAC · MPO and LC patch cords
MPO patch cord with IL/RL test labels
MPO OM3 8-fiber 20 m · with IL/RL test label

Optical modules 1G – 200G

Matched on three things: rate, wavelength and reach. At the same rate, short runs use multimode (850 nm) and long runs single-mode (1310 nm / 1550 nm); the two never mix.

RatePackageTypical wavelength / reachFiber and connectorTypical use
1GSFP850nm / 550m;1310nm / 10kmMultimode / single-mode · LCAccess switch uplinks, CCTV backhaul
10GSFP+850nm / 300m;1310nm / 10km、40kmMultimode / single-mode · LCFloor to core, server access
10G (copper)SFP+ RJ45Cat6a / 30mRJ45 copperShort copper runs, replacing copper-port switches
25GSFP28850nm / 100m;1310nm / 10kmMultimode / single-mode · LC25G server access, leaf-spine
40GQSFP+850nm / 150m(SR4);1310nm / 10km(LR4)MPO or LCAggregation layer, storage networks
100GQSFP28850nm / 100m(SR4);1310nm / 10km(LR4)MPO or LCCore interconnect, data center spine
200GQSFP-DD / QSFP56850nm / 100m(OM4)MPO-16 / MPO-24AI training clusters, high-density core
We issue a compatibility list against your switch model, so a coding mismatch never leaves a module unrecognized.

AOC active optical / DAC direct-attach copper

Inside a rack, 1–5 m is DAC (cheaper, lower latency); between racks or beyond 5 m, AOC (lighter, longer). Neither needs separate optics.

TypeRateKey specifications
10G SFP+ DAC10.3125 GbpsSingle-lane NRZ, BER < 1E-15, 0–70 °C, 3.3 V, LSZH jacket, SFF-8636 / I2C management
25G SFP28 DAC25.78125 GbpsSingle-lane 25G NRZ, BER < 1E-15, 0–70 °C, SFP28 MSA compliant
100G QSFP28 DAC103.125 Gbps4 × 25G NRZ, BER < 1E-15, QSFP28 MSA and SFF-8636 compliant
200G QSFP-DD / QSFP56 DAC200 Gbps8-lane or 4-lane, hot-swappable, 0–70 °C
200G QSFP28-DD AOC206.25 Gbps8-lane full duplex, 850 nm VCSEL + PIN, integrated CDR; OM3 70 m / OM4 100 m; under 4 W per end
200G DD → 2×100G AOC200 → 100 GbpsBreakout (one 200G end, two 100G ends) for high-density port splitting
Bend radius and tray width are routinely overlooked on AOC / DAC. In dense rack cabling, confirm diameter and bend radius together — otherwise the door will not close.

MPO multi-fiber patch cords

The workhorse for short 40G / 100G links. Fiber count, polarity and fiber type must all line up — get one wrong and the link stays down.

ItemSpecification
ConnectorMPO / UPC / female (F); male to order
Fiber count8 and 12 fiber (standard); 24 fiber to order
Fiber typeOM3 / OM4 multimode; single-mode (SM)
Loss gradeElite Loss, insertion loss ≤ 0.35 dB
Interchangeability / repeatability≤ 0.2 dB / ≤ 0.2 dB
Mating cycles800–1,000 cycles
Operating temperature−40 ~ 75 ℃
PolarityType B (straight); Type A / Type C to order
Factory testInsertion and return loss measured on every cord, with an IL/RL label
The classic polarity trap: both ends must be Type B. Mix A and B and the link either runs degraded or not at all.

LC single-mode / multimode patch cords

Color follows the fiber type; polish follows the port. The color is not decoration — on site it is the main cue for telling fiber types apart.

TypeJacket colorNotes
OS2 single-modeYellow9/125 μm, long reach (over 10 km), with 1310 / 1550 nm modules
OM3 multimodeAqua50/125 μm, 850 nm VCSEL, 300 m at 10G
OM4 multimodeViolet or aqua50/125 μm, higher bandwidth: 400 m at 10G, 150 m at 100G
Length—1/2/3/5/10 m standard; made to site length
Polish—UPC (blue) standard; APC (green) for PON and long single-mode runs
Single-mode and multimode modules do not interchange, and neither do their patch cords. Mix them and the port either stays dark or flaps.

How to choose: the matching method

01

Start with the ports at both ends

SFP+ or QSFP28, LC or MPO — that decides package and connector. Get this step wrong and everything after it is wrong.

02

Then the reach and the fiber already there

Whether the existing fiber is single-mode or multimode sets the wavelength; distance decides SR (short reach) or LR (long reach). If the fiber stays, the module has to follow it.

03

Then check compatibility

Some switches lock modules to a specific coding. We issue a compatibility list for your model and, where needed, supply pre-coded units.

Delivery and testing

01

Batch consistency

One batch, one batch number, so mixing lots does not make links unstable. Large projects can be stocked under a project number.

02

Tested cord by cord

Every MPO and patch cord is measured for insertion and return loss, with the label on the part; modules are sampled or fully tested by batch, and the reports ship with the goods.

03

Packing and labeling

Bagged and labeled by rack or floor, so each part says where it goes and the crew does not re-sort on site.

04

Spares and replenishment

Common rates and lengths are held in stock; urgent replenishment ships same day or next, so one patch cord never stops the job.

A model list, or a quote first?

Send the equipment model, link distance and quantity and we return a compatibility list and a quote — or a full datasheet first for you to check.

Request the datasheet and a quote →

One wrong cable, a whole link down. Check first, then order.

Request the selection list →